我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|Table of Contents|

关于铁质粉碎机对制备试样污染的研究(PDF)

《南京林业大学学报(自然科学版)》[ISSN:1000-2006/CN:32-1161/S]

Issue:
1986年01期
Page:
137-141
Column:
研究论文
publishdate:
1900-01-01

Article Info:/Info

Title:
STUDIES ON THE CONTAMINATION OF THE SAMPLES PREPARED WITH FERROUS WILEY MILL
Article ID:
1000-2006(1986)01-0137-05
Author(s):
Bi Xiaochun
Faculty of Basic Courses
Keywords:
Magnetism measurement Ferrous Wiley Mill Gouy balance Analytical chemistry
Classification number :
-
DOI:
10.3969/j.jssn.1000-2006.1986.01.016
Document Code:
A
Abstract:
The magnetic changes of the samples prepared from ferrous Wiley Mill have been studied with the economic and fast method of Gouy balance. The results show that the sample was very seriously contaminated by iron, when ferrous content is small in the sample, the error determined is up to 5~6 times. Therefore, a sample prepared from ferrous wiley Mill should not be used to determine the minute iron content in it.

References

-