Title:
Test accuracy analysis of atomizing nozzle test bed
Article ID:
1000-2006(2013)06-0137-05
Author(s):
WU Xiaowei12 ZHOU Hongping1* XU Linyun1 RU Yu1
1.College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing 210037, China;
2. Jiangsu Agricultural Machinery Technology Extension Station, Nanjing 210017, China
Keywords:
atomization nozzle test-bed nozzle parameters pressure sensor flow sensor
Classification number :
S491
DOI:
10.3969/j.issn.1000-2006.2013.06.027
Document Code:
A
Abstract:
In order to improve testing precision of test bed and the test accuracy of atomizing nozzle test bed be researched. Firstly, reference nozzle parameters were calibrated, and then, the measurement accuracy of pressure sensors and flow sensors were calibrated. Based on the calibration, the test errors of distributions of test bed was analyzed, finally, inspect the test-bed through amendment value. Through calibration can draw: At different pressures, the maximum error between the atomizing nozzle testing value and the reference value is 2.70%. The correction value of pressure sensor is 0.01 MPa. The error between the average flow sensor measuring and reference value is 1.2%. Under the same pressure, the maximum error between the average flow value of test-bed and reference value is 2.84%. The measuring errors become decreases with the measuring time increase. When measure time reaches to 200 s, the error basically stable, the maximum error is 0.8%. Through testing of amendment test system can found that the maximum error between the measurements of test-bed and reference values is 0.7%, showing that the test-bed can meet high-accuracy measurement requirements.

References

[1] Derksen R C, Jiang C. Automated detection of fluorescent spray deposits with a computer vision system[J]. Transactions of the ASABE,1995,38(6):1647-1653.
[2] Bouse L F. Effect of nozzle type and operation on spray droplet size[J]. Transactions of the ASABE, 1994,37(5):1380-1400.
[3] Bouse L F, Carlton J B, Kerk I W, et al. Nozzle selection for optimizing deposition and minimizing spray drift for AT 502 air tractor[J]. Transaction of the ASABE, 1994,37(6):1725-1731.
[4] Smith D B. Uniformity and recovery of broadcast spray using fan nozzles[J]. Trans of the ASABE, 1992, 35(1):39-44.
[5] Ayers P D, Rogowski S M, Kimble B L. An investigation of factors affecting sprayer control system performance[J]. Applied Engineering in Agriculture, 1990,6(6):701-706.
[6] Wang L, Zhang N, Slocombe J W. Experimental analysis of spray distribution pattern uniformity for agricultural nozzles[J]. Applied Engineering in Agriculture, 1995,11(1):51.
[7] John C Wise, Paul E Jenkins, Annemiek M C Schilder. Sprayer type and water volume influence pesticide deposition and control of insect pests and diseases in juice grapes[J]. Crop Protection, 2010, 29(6):378-385.
[8] 坎杂,张新昌,张立新,等.PZS-4型喷雾机械综合试验台的设计研究[J].石河子大学学报:自然科学版,1997(1):61-65.Kan Z, Zhang X C, Zhang L X, et al. Design researches on PZS-4 type spraying machine multiple trial table[J]. Journal of Shihezi University:Natural Science, 1997(1):61-65.
[9] 薛新宇,柳平曾,龚艳,等.喷头综合性能测试实验台的研制及应用[J].中国农机化,2006(2):94-97.Xue X Y, Liu P Z, Gong Y, et al. Design and application of test-bed for precision testing nozzle integrative performance[J]. Chinese Agricultural Mechanization, 2006(2):94-97.
[10] 张红霞,张伟,胡军,等. 喷雾机械综合试验台的设计[J]. 农机化研究,2006(7):93-95.Zhang H X, Zhang W, Hu J, et al. Design of the sprayer machinery synthesize experiment’s table[J]. Journal of Agricultural Mechanization Research,2006(7):93-95.
[11] 柳平增,丁为民,薛新宇,等.植保喷头综合性能测试专用数控系统的设计[J].计算机测量与控制,2006,14(12):1602-1604.Liu P Z, Ding W M, Xue X Y, et al. Design of special numeric control system for test crop-protection nozzle integrative performance[J]. Computer Measurement & Control, 2006,14(12):1602-1604.
[12] 祁力钧, 傅泽田. 不同条件下喷雾分布试验研究[J].农业工程学报,1999,15(2):107-111.Qi L J, Fu Z T. Experimental study on spray deposition uniformity[J]. Transactions of the Chinese Society of Agriculture Engineering, 1999,15(2):107-111.
[13] 陈志刚,吴春笃,杨学军. 喷杆喷雾雾量的分布均匀性[J].江苏大学学报:自然科学版,2008,29(6):465-468.Chen Z G, Wu C D, Yang X J. Spray distribution uniformity of boom spraying[J]. Journal of Jiangsu University:Natural Science Edition, 2008,29(6):465-468.
[14] 宋坚利,何雄奎,杨雪玲. 喷杆式喷雾机雾流方向角对药液沉积影响的试验研究[J].农业工程学报,2006,22(6):96-99.Song J L, He X K, Yang X L. Influence of nozzle orientation on spray deposits[J]. Transactions of the Chinese Society of Agriculture Engineering, 2006,22(6):96-99.
[15] ISO. 5682-1:1996(E)Equipment for Crop Protection—Spraying Equipment—Part 1: Test Methods for Sprayer Nozzles[S]. Switzerland: International Organization for Standardization,1996.
[16] 南京农业机械化研究所,中国农业机械化科学研究院. JB/T 9782—1999 植保机械 通用试验方法[S].北京:国家机械工业局,1999.
[17] ISO. 11545:2001(E)Agricultural Irrigation Equipment—Centrepivot and Moving Lateral Irrigation Machines with Sprayer or Sprinkler Nozzles—Determination of Uniformity of Water Distribution[S]. Switzerland:International Organization for Standardization,2001.
[18] 傅泽田,祁力钧,王秀.农药喷施技术的优化[M]. 北京:中国农业科学出版社,2002.
[19] 王荣. 植保机械学[M].北京:机械工业出版社,1990.

Last Update: 2013-11-30