我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|Table of Contents|

电磁屏蔽碳毡叠层型胶合板的性能研究(PDF/HTML)

《南京林业大学学报(自然科学版)》[ISSN:1000-2006/CN:32-1161/S]

Issue:
2017年01期
Page:
156-162
Column:
研究论文
publishdate:
2017-01-31

Article Info:/Info

Title:
Research on properties of plywood laminated with electromagnetic shielding carbon felts
Article ID:
1000-2006(2017)01-0156-07
Author(s):
HOU Junfeng1 2 FU Feng1 LU Keyang1*
1.Key Laboratory of Wood Science and Technology, State Forestry Administration, Research Institute of Wood Industry, CAF, Beijing 100091, China;
2.College of Engineering, Zhejiang Agriculture and Forestry University, Lin’an 311300, China
Keywords:
electromagnetic shielding carbon felt laminated structure plywood shielding effectiveness shear strength
Classification number :
TS653.3
DOI:
10.3969/j.issn.1000-2006.2017.01.024
Document Code:
A
Abstract:
【Objective】Based on the structural model of laminated electromagnetic shielding, electromagnetic shielding carbon felts were laminated with poplar veneers to manufacture electromagnetic shielding plywood to efficiently minimize the hazard caused by electromagnetic interference. Effects of the carbon fiber filler content of the electromagnetic shielding carbon felt on electromagnetic shielding performance and bonding performance of the manufactured plywood were investigated. In addition, the feasibility of the double-layer laminated shielding structure was analyzed.【Method】Shielding effectiveness(SE)and shear strength of the plywood laminated with electromagnetic shielding carbon felts were investigated by using a coaxial test and shear test, respectively. Furthermore, carbon fiber distributions in the plane and cross-sections of the electromagnetic shielding carbon felt were observed by using a metallurgic microscope.【Result】It was observed that a “three-dimensional electromagnetic shielding network” was starting to form in the electromagnetic shielding carbon felt as the carbon fiber filler content increased to 25 g/m2. The results revealed that the SE of plywood laminated with electromagnetic shielding carbon felts increased with increasing carbon fiber filler content. It was found that SE of the plywood, which was laminated with a double-layer electromagnetic shielding carbon felt(120 g/m2), ranged from 52.61 to 68.37 dB(100 kHz-1.5 GHz), and had a medium shielding performance(60-90 dB). Additionally, plywood laminated with the double-layer electromagnetic shielding carbon felts exhibited higher SE than the plywood laminated with the single-layer electromagnetic shielding carbon felt at the same total carbon fiber filler content. However, the SE advantage of the former was reduced with the increase in carbon fiber filler content and testing frequency. The results also revealed that the plywood laminated with double-layer electromagnetic shielding carbon felt exhibited greater shear strength than plywood laminated with single-layer electromagnetic shielding carbon felt. The shear strength of plywood laminated with electromagnetic shielding carbon felts exceeded the minimum value of 0.7 MPa, which is required by the Chinese plywood standard of GB/T 9846.3—2004. 【Conclusion】 Electromagnetic shielding performance and bonding performance of the manufactured plywood are effectively improved after the lamination of electromagnetic shielding carbon felts. Furthermore,the laminated structure model was proved to be feasible in this study.

References

[1] VAN DER TOGT R, VAN LIESHOUT E J, HENSBROEK R, et al. Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment[J]. JAMA, 2008, 299(24): 2884-2890. DOI:10.1001/jama.299.24.2884.
[2] ALMEID L C. Environment, biologic rhythms, depression and EM radiations[J]. Research Journal of Environmental and Earth Sciences, 2011(2): 81-89.
[3] AL-NIMER M, MAJEED A, ALHUSSEINY A. Electromagnetic energy radiated from mobile phone alters electrocardiographic records of patients with ischemic heart disease[J]. Annals of Medical and Health Sciences Research, 2012, 2(2): 146-151. DOI:10.4103/2141-9248.105662.
[4] KUHN M G, ANDERSON R J. Soft tempest: hidden data transmission using electromagnetic emanations[J].Information Hiding, 1998,1525: 124-142. DOI:10.1007/3-540-49380-8_10.
[5] MAO J, LI Y M, ZHANG J M,et al. Model for electromagnetic information leakage[J]. TELKOMNIKA Indonesian Journal of Electrical Engineering, 2014, 12(2):894-898. DOI:10.11591/telkomnika.v12i2.4010.
[6] 卢克阳, 傅峰, 蔡智勇, 等. 铜纤维填充脲醛树脂导电膜片的电磁屏蔽性能[J]. 林业科学, 2011, 47(7): 166-171.DOI:10.11707/j.001-7488.20110726 LU K Y, FU F, CAI Z Y, et al. Electromagnetic shielding property of UF adhensive conductive sheets filled with copper fibers[J]. Scientia Silvae Sinicae, 2011, 47(7): 166-171.
[7] 于名讯, 徐勤涛, 庞旭堂, 等. 电磁屏蔽材料的研究进展[J]. 宇航材料工艺, 2012, 42(4): 12-15. DOI:10.3969/j.issn.1007-2330.2012.04.003. YU M X, XU Q T, PANG X T, et al. Research progress of electromagnetic interference shielding materials[J].Aerospace Materials & Technology, 2012, 42(4): 12-15.
[8] 朱家琪, 罗朝晖, 黄泽恩. 金属网与木单板的复合[J]. 木材工业, 2001, 15(3): 5-7. DOI:10.3969/j.issn.1001-8654.2001.03.002. ZHU J Q, LUO Z H, HUANG Z E. Composition of wire net and wood veneer[J]. China Wood Industry, 2001, 15(3): 5-7.
[9] LU K Y, FU F, CAI Z Y, et al. Nondestructive methods for evaluating mechanical properties of wood electromagnetic shielding composite [G]. 16th International Symposium on Nondestructive Testing and Evaluation of Wood, 2009: 208-215.
[10] 卢克阳, 傅峰, 蔡智勇, 等. 导电膜片叠层型电磁屏蔽胶合板屏蔽持久性研究[J]. 南京林业大学学报(自然科学版), 2010, 34(5): 79-82. DOI:10.3969/j.issn.1000-2006.2010.05.017. LU K Y, FU F, CAI Z Y, et al. Study on shielding permanence of electromagnetic shielding plywood laminated with conductive sheets[J]. Journal of Nanjing Forestry University(Natural Sciences Edition), 2010, 34(5): 79-82.
[11] CHANG H, YEH Y M, HUANG K D. Electromagnetic shielding by composite films prepared with carbon Fiber, Ni nanoparticles, and multi-walled carbon nanotubes in polyurethane[J]. Materials Transactions, 2010, 51(6):1145-1149. DOI:10.2320/matertrans.m2009408.
[12] 刘贤淼, 傅峰. 导电粉末与木单板复合材料性能研究[J]. 南京林业大学学报(自然科学版), 2009, 33(2): 95-98. DOI:10.3969/j.issn.1000-2006.2009.02.023. LIU X M, FU F. Study on performance of electro-conductive powder and veneer composite[J]. Journal of Nanjing Forestry University(Natural Sciences Edition), 2009, 33(2): 95-98.
[13] 刘贤淼, 傅峰. 不锈钢纤维/木单板复合电磁屏蔽功能胶合板[J]. 木材加工机械, 2008, 19(5): 22-26,30.DOI:10.3969/j.issn.1001-036X.2008.05.006. LIU X M, FU F. Stainless stee fiber/veneer composite electromagnetic-shield effectiveness plywood[J].Wood Processing Machinery, 2008, 19(5): 22-26,30.
[14] CHEN G, WU B, CHEN Z F. Shielding performance of metal fiber composites[J]. Transactions of Nonferrous Metals Society of China, 2004, 14(S1):493-496.
[15] PERUMALRAJ R, DASARADAN B S, ANBARASU R, et al. Electromagnetic shielding effectiveness of copper core-wovenfabrics[J]. Journal of the Textile Institute, 2009, 100(6): 512-524. DOI:10.1080/00405000801997587.
[16] MATSUMOTO N, NAIRN J A. The fracture toughness of medium density fiberboard(MDF)including the effects of fiber bridging and crack-plane interference[J]. Engineering Fracture Mechanics, 2009, 76(18): 2748-2757. DOI:10.1016/j.engfracmech.2009.04.007.
[17] KHAN T A, GUPTA A, JAMARI S S, et al. Synthesis and characterization of carbon fibers and their application in wood composites[J]. Bio Resources, 2013, 8(3):4171-4184. DOI:10.15376/biores.8.3.4171-4184.
[18] WANG X, FU X, CHUANG D D L. Electromechanical study of carbon fiber composites[J]. Journal of Materials Research, 1998, 13(11): 3081-3092. DOI:10.1557/jmr.1998.0420.
[19] JOU W S. A novel structure of woven continuous-carbon fiber composites with high electromagnetic shielding[J].Journal of Electronic Materials, 2004, 33(3): 162-170. DOI:10.1007/s11664-004-0175-x.
[20] 卢克阳, 傅峰. 电磁屏蔽胶合板同轴测试方法的改进[J]. 南京林业大学学报(自然科学版), 2008, 32(1): 53-56. DOI:10.3969/j.issn.1000-2006.2008.01.012. LU K Y, FU F. Improvement of coaxial test method for the electromagnetic shielding plywood[J]. Journal of Nanjing Forestry University(Natural Sciences Edition), 2008, 32(1): 53-56.
[21] 卢克阳, 傅峰, 蔡智勇, 等. 铜纤维/脲醛树脂复合膜片的导电性能[J]. 林业科学, 2009, 45(7): 169-174. DOI:10.3321/j.issn:1001-7488.2009.07.030. LU K Y, FU F, CAI Z Y, et al. Conductive propenies of uf adllesive sheets filled with copper fiber[J].Scientia Silvae Sinicae, 2009, 45(7): 169-174.
[22] 王立娟, 李坚, 刘一星. 化学镀法制备电磁屏蔽木材-Ni-P复合材料研究[J]. 材料科学与工艺, 2006, 14(3): 296-299,304. DOI:10.3969/j.issn.1005-0299.2006.03.021. WANG L J, LI J, LIU Y X. Study on electromagnetic shielding wood ni-p composite prepared by electroless nickel plating[J]. Materials Science and Technology, 2006, 14(3): 296-299,304.
[23] LU K, FU F, SUN H L, et al. Bonding technology of electromagnetic shielding plywood laminated with conductive sheets[J]. Wood Research, 2013, 58(3):465-474.
[24] 张晓宁. 层状复合电磁屏蔽材料的设计与制备[D]. 北京:北京工业大学, 2000. ZHANG X N. Design and manufacture of laminated electromagnetic shielding composites [D]. Beijing: Beijing University of Technology, 2000.
[25] 卢克阳, 傅峰, 蔡智勇, 等. 导电膜片叠层型电磁屏蔽胶合板的性能研究[J]. 建筑材料学报, 2011, 14(2): 207-211,233. DOI:10.3969/j.issn.1007-9629.2011.02.012. LU K Y, FU F, CAI Z Y, et al. Study of porperties of electromagnetic shielding plywood laminated with conductive sheets[J]. Journal of Building Materials, 2011, 14(2): 207-211,233.

Last Update: 2017-01-30