南京林业大学学报(自然科学版) ›› 1997, Vol. 21 ›› Issue (02): 58-62.doi: 10.3969/j.jssn.1000-2006.1997.02.013

• 研究论文 • 上一篇    下一篇

燃烧室-喷管工作频率计算方法的研究

周宏平;程祥之;蒋本浩   

  1. 南京林业大学机械工程学院
  • 出版日期:1997-06-18 发布日期:1997-06-18

A STUDY ON THE METHOD OF CALCULATING THE PULSATING FREQUENCY OF A COMBUSTION CHAMBER AND EXHAUST TUBE

Zhou Hongping Cheng Xiangzhi Jiang Benhao   

  1. College of Mechanical Engineering Nanjing Forestry University Nanjing 210037
  • Online:1997-06-18 Published:1997-06-18

摘要: <正>烟雾机是森林病虫害防治中的主要设备之一,燃烧室-喷管是烟雾机的主要部分。笔者对燃烧室-喷管工作频率的理论计算方法进行细致的分析与推导,并结合实际进行了试验验证。

Abstract: A fogger in one of main devices used in forestry disease and insect control. A combustion chamber and exhaust tube(C.E.T.) is one of the main units of a fogger. The theoretical formula of calculating pulsating frequency of a C.E.T. is analyzed and deduced in the paper. It is proved that the test data of pulsating frequency of a C.E.T. will meet accurately the result calculated from the formula which provides the theoretical basis for C.E.T. designing.