南京林业大学学报(自然科学版) ›› 2014, Vol. 38 ›› Issue (04): 140-144.doi: 10.3969/j.issn.1000-2006.2014.04.027

• 研究论文 • 上一篇    下一篇

阻燃型丙烯酸酯乳液胶黏剂的性能研究

于向东1,3,刘 娟1,陈日清1,2*,王春鹏1,2,卜洪忠3   

  1. 1.中国林业科学研究院林产化学工业研究所,生物质化学利用国家工程实验室,国家林业局林产化学工程重点开放性实验室,江苏省生物质能源与材料重点实验室,江苏 南京 210042;
    2.中国林业科学研究院林业新技术研究所,北京 100091;
    3.南京工业大学理学院,江苏 南京 210009
  • 出版日期:2014-07-31 发布日期:2014-07-31
  • 基金资助:
    收稿日期:2013-09-09 修回日期:2014-04-18
    基金项目:中央级公益性科研院所基本科研业务费专项资金项目(CAFINT2011K01)
    第一作者:于向东,硕士生。*通信作者:陈日清,副研究员, 博士。E-mail:michaelmao77@163.com。
    引文格式:于向东,刘 娟,陈日清,等. 阻燃型丙烯酸酯乳液胶黏剂的性能研究[J]. 南京林业大学学报:自然科学版,2014,38(4):140-144.

Study on the properties of flame retardant acrylate emulsion adhesive

YU Xiangdong1, 3, LIU Juan1, CHEN Riqing1,2*, WANG Chunpeng1, 2, BU Hongzhong3   

  1. 1.Institute of Chemical Industry of Forest Products,CAF;
    National Engineering Lab. for Biomass Chemical Utilization, Key and Open Lab. on Forest Chemical Engineering,SFA;
    Jiangsu Provincal Key Lab. of Biomass Energy and Material,Nanjing 210042, China;
    2. Institute of Forest New Technology, CAF, Beijing 100091, China;
    3. School of Science, Nanjing University of Technology, Nanjing 210009, China
  • Online:2014-07-31 Published:2014-07-31

摘要: 采用机械共混方式获得了氢氧化铝(ATH)、三聚氰胺磷酸盐(MP)和MP/季戊四醇(PER)3种阻燃型丙烯酸酯乳液胶黏剂,并研究了3种体系的阻燃剂种类、添加量、配比对阻燃性能、力学性能、热稳定性的影响。结果表明:体系的拉伸强度随阻燃剂添加量的增加而降低,氧指数(LOI)随阻燃剂添加量的增加而增加; 同水平下,ATH改性胶黏剂体系残渣率较高; 锥形量热仪结果表明各类阻燃剂的加入均能有效减少胶黏剂体系的热释放速率(HRR)、质量损失速率(MLR)和烟释放速率(SPR); 扫描电镜(SEM)表明当MP与PER质量比为3:1时,改性胶黏剂体系的膨胀型阻燃效果最佳。

Abstract: Three kinds of acrylate emulsion adhesive modified with aluminum hydroxide(ATH), melamine pyrophosphate(MP)and MP/pentaerythritol(PER)were prepared by mechanical mixing method. The effects of the types, the amounts and the ratios of the flame retardant on the fire retardant behavior, mechanical property and the thermal stability of the acrylate emulsion adhesive were compared. The results showed that the tensile strength of the adhesive decreased and limiting oxygen index(LOI)increased with the increment of supplementing amount of the flame retardant, and adhesive modified with ATH had higher residue content at the same level with the comparision of the other two flame-retardants’ systems. The cone calorimeter results indicated that the addition of various flame retardant could effectively reduce the heat release rate(HRR), the mass loss rate(MLR)and the smoke production rate(SPR)of the adhesive. The scanning electron microscopy(SEM)showed that the adhesive modified with the ratio of intumescent flame retardant MP/PER to 3/1 had the best flame retardant effect.

中图分类号: