关于铁质粉碎机对制备试样污染的研究

毕孝春

南京林业大学学报(自然科学版) ›› 1986, Vol. 10 ›› Issue (01) : 137-141.

PDF(331691 KB)
PDF(331691 KB)
南京林业大学学报(自然科学版) ›› 1986, Vol. 10 ›› Issue (01) : 137-141. DOI: 10.3969/j.jssn.1000-2006.1986.01.016
研究论文

关于铁质粉碎机对制备试样污染的研究

  • 毕孝春
作者信息 +

STUDIES ON THE CONTAMINATION OF THE SAMPLES PREPARED WITH FERROUS WILEY MILL

  • Bi Xiaochun
Author information +
文章历史 +

摘要

<正>用经济、快速的古埃天平法,研究了铁质粉碎机制备试样的磁性变化。其结果表明铁的污染是极其严重的。因此,测定试样中的微量铁,决不能用铁质粉碎机制备试样。

Abstract

The magnetic changes of the samples prepared from ferrous Wiley Mill have been studied with the economic and fast method of Gouy balance. The results show that the sample was very seriously contaminated by iron, when ferrous content is small in the sample, the error determined is up to 5~6 times. Therefore, a sample prepared from ferrous wiley Mill should not be used to determine the minute iron content in it.

引用本文

导出引用
毕孝春. 关于铁质粉碎机对制备试样污染的研究[J]. 南京林业大学学报(自然科学版). 1986, 10(01): 137-141 https://doi.org/10.3969/j.jssn.1000-2006.1986.01.016
Bi Xiaochun. STUDIES ON THE CONTAMINATION OF THE SAMPLES PREPARED WITH FERROUS WILEY MILL[J]. Journal of Nanjing Forestry University (Natural Sciences Edition). 1986, 10(01): 137-141 https://doi.org/10.3969/j.jssn.1000-2006.1986.01.016